최신 API Certification API-1169 무료샘플문제:
1. All pipe installed off shore ,under water not more than 200 ft (60) meters deep but less than 12 ft must have ______ in cover of soil. ( except in the Gulf of Mexico and its inlets)
49 CFR 192.319
A) 8
B) 5
C) 36
D) 48
2. Facility, Commissioning, and Pre-start-up Review, inspectors should understand owner/operator MOT requirements and why adherence to them can prevent incidents. In the case of construction MOC concepts do what?
A) Recognize, document, and communicate such factors as change and personnel, organizational make up, physical configuration/layouts, equipment, site conditions, materials, and procedures if required.
B) Management with regard to quality, can include establishing quality policies in quality objectives and processes to achieve these quality objectives through quality planning quality assurance quality control and quality improvement(ISO 9000 3.3.4)
C) They shall be accepted as meeting the requirements provided they break at not less than 95% of the tensile strength of the material(API 1104 5.3)
D) Action to illuminate the cause of a potential nonconformity or other potential undesirable situation.(Preventative action is taken to prevent occurrence were as correct of action is taken to prevent recurrence)(ISO 9000 3.12.1)
3. Deficiencies, unsatisfactory work, thefts, vandalism,missing materials/property or suspicious activities are all ___________________ by inspector.
A) Benchmarking
B) Required reporting
C) Clearing
D) Quality improvement
4. Define Inspector
A) An individual qualified to monitor, assess, evaluate, verify, discuss, decide, resolve, report, and document pipeline construction activities to ensure the requirements of the design, drawings, specifications, regulations, and Industry practises are being met safely, effectively, and in an environmentally sound manner.
B) Action to illuminate the cause of a non-conformity in to prevent recurrence.(correct of action is taken to prevent recurrence where as preventative action is taken to prevent occurrence)(ISO 9000 3.12.2)
C) Is the area in which soil must be removed by non-mechanical means such as (hand digging, pot-holing, or hydro-Vac) rather than mechanical means. It is an area within 2 feet of the existing facilities or the distance mandated by state law where applicable, whichever is greater.
D) Confirmation, through the provisions of objective evidence, that the requirements for a specific intended use or application have been fulfilled.(The objective evidence needed for a validation is the result of a test or other form of determination such as performing alternative calculations or reviewing documents)(ISO 9000 3.8.13)
5. Define Owner
A) An individual qualified to monitor, assess, evaluate, verify, discuss, decide, resolve, report, and document pipeline construction activities to ensure the requirements of the design, drawings, specifications, regulations, and Industry practises are being met safely, effectively, and in an environmentally sound manner.
B) Is the singular point of contact identified within the company of the crossing company and the owner who has the responsibility to communicate about the safely managed crossing. There will be a cross and Company designated contact and an owner designated contact.
C) Is the entity that owns our operates the existing pipeline facilities. The owner may designate a third-party or parties to perform the tasks necessary to enable a safe crossing of its facilities by crossing company but remains responsible for the work performed by such third-party.
D) Is the vertical separation between the existing pipeline and facilities and where the new pipeline is being installed. The recommended crossing clearance distance between the new pipeline and the existing facilities is two feet (24"). The minimum distance is one foot (12"). The new pipeline should be installed at a level depth across the ROW, if practicable.
질문과 대답:
| 질문 # 1 정답: C | 질문 # 2 정답: D | 질문 # 3 정답: A | 질문 # 4 정답: A | 질문 # 5 정답: C |